5x RJ45 Ports
Get high speed data transfer rates easily by connecting up to 5x Cat5e or Cat6 UTP cables.
5x RJ45 Ports
1x SFP Port
10/100/1000
120W Power over Ethernet
Get high speed data transfer rates easily by connecting up to 5x Cat5e or Cat6 UTP cables.
Provide flexible fiber connectivity easily with extremely high speeds with low loss in a compact design.
Utilizing auto-negotiation, this switch detects cable type, power needs, and automatically selects the best speed.
Provides up to 120 watts of Power over Ethernet budget at 30W per port.
Built for endurance, the OVPOE4G-DR-SFP is constructed out of a durable metal housing.
PoE Switch |
|
Power Supply | Input 12~56VDC |
Ethernet Standard | IEEE 802.3/u/z/ab, 10Base-T, 100Base-TX, 1000Base-T and 1000Base-X |
Network Ports | PoE Ports: 4 10/100/1000Mbps RJ45 Uplink: 1 Gigabit RJ45 + 1SFP(1.25Gbps) |
Transmission Distance | 1~5 Ethernet Port: 0~100m 1 SFP: According to different SFP |
Transmission Media | 5 RJ45 Port: Cat5e/6 UTP cable 1 SFP: LC interface optical fiber |
MAC Address List | 8K |
Switch Capacity | 12G |
Surge Immunity | Level 3, executive standard IEC61000-4-5 |
Electrostatic Protection | 1a touch electric discharge: level 3 1a Air discharge: level 3 Executive standard IEC61000-4-2 |
Working & Storage Temperatures | -40 ~ +85 °C |
Humidity | 0-95% |
Dimensions (L*W*H) | 5.98” x 4.47” x 3.5” |
Power Supply |
|
OUTPUT | |
DC VOLTAGE | 48V |
RATED CURRENT | 2.5A |
CURRENT RANGE | 0 ~ 2.5A |
RATED POWER | 120W |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p |
VOLTAGE ADG. RANGE | 48 ~ 55V |
VOLTAGE TOLERANCE Note.3 | ±1.0% |
LINE REGULATION | ±0.5% |
LOAD REGULATION | ±1.0% |
SETUP, RISE TIME | 1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load |
HOLD UP TIME (Typ.) | 16ms/230VAC 10ms/115VAC at full load |
INPUT | |
VOLTAGE RANGE Note.6 | 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 89% |
AC CURRENT (Typ.) | 2.25A/115VAC 1.3A/230VAC |
INRUSH CURRENT (Typ.) | 20A/115VAC 35A/230VAC |
LEAKAGE CURRENT | <1mA / 240VAC |
PROTECTION | |
OVERLOAD | 105 ~ 130% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 56 ~ 65V |
Protection type : Shut down o/p voltage, re-power on to recover | |
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down |
ENVIRONMENT | |
WORKING TEMP. | -20 ~ +70℃(Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/℃(0 ~ 50℃) |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
SAFETY & EMC (Note 4) | |
SAFETY STANDARDS | UL508, TUV BS EN/EN62368-1, EAC TP TC 004 approved;(meet BS EN/EN60204-1) |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020 |
NOTE | |
1. All parameters Not specifically mentioned are measured at 230VAC input, rated load and 25°C of Ambient temperature. | |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair wire terminated with a 0.1uf & 47uf parallel capacitor. | |
3. Tolerance: Includes set up tolerance, line regulation and load regulation. | |
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |
5. Installation clearences: 40mm on top, 20mm on bottom, 5mm on the left and right sides are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. | |
6. Derating may be needed under low input voltage. Please check the derating curve for more details. | |
7. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m (6500ft). |
Accessories |
---|